Selectable Charge Profiles:
F1 - Float: Regulates the battery voltage at just below the gassing threshold. Best for starting batteries, and gel's.
F2 - Gas & timed shut off: Timer trips at the gassing threshold. Batteries are allowed to gas for three hours before shut off. Best for deep cycle batteries.
F3 - Gas & float: Timer trips at the gassing threshold. Batteries are allowed to gas for three hours before dropping into indefinite float/maintenance mode. Best for deep cycle batteries that may see long periods of inactivity.
F4 - AGM: Timer trips at the absorption threshold. Batteries stay in absorption mode for three hours before dropping into indefinite float/maintenance mode.
F5 -Lithium Ion: Can be set to a specific voltage and will shut off when current falls to 10% of charger rating.